Keyword: synchrotron-radiation
Paper Title Other Keywords Page
WEP002 Study of Visible Synchrotron Radiation Monitor on SOLEIL Booster booster, extraction, synchrotron, emittance 331
 
  • A. Moutardier, G. Cauchon, M. Chevrot, Z. Fan, N. Hubert, S. Kubsky, M. Labat, M. Thomasset
    SOLEIL, Gif-sur-Yvette, France
 
  In the scope of SOLEIL II, the booster must also be upgraded to reduce from 130 to 5~nm.rad the emittance of the beam delivered to the ring. Control of the emittance in the booster will become crucial to ensure the nominal performance of the storage ring injection. The SOLEIL I booster is already equipped with a Visible Synchrotron Radiation Monitor (MRSV). This equipment, made of an extraction mirror and a simple optical system, was originally planned to be used only for beam presence verification but has not been used routinely for operation since the commissioning in 2005. The control and acquisition systems had to be refreshed to be usable again and allow the beam size measurement along the booster energy ramp. The extraction mirror was replaced due to unexpected degradation leading to a second spot appearing on the camera. This paper traces back the MRSV upgrades from understanding the cause of mirror degradation until mirror replacement and the first proper beam visualisation, achieved at the beginning of 2023.  
poster icon Poster WEP002 [1.550 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2023-WEP002  
About • Received ※ 04 September 2023 — Revised ※ 09 September 2023 — Accepted ※ 12 September 2023 — Issue date ※ 16 September 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEP005 Effect of Incoherent Depth of Field for Bean Halo Measurement with the Coronagraph in SuperKEKB simulation, optics, radiation, synchrotron 335
 
  • T.M. Mitsuhashi, H. Ikeda, G. Mitsuka
    KEK, Ibaraki, Japan
 
  The incoherent depth-of-field due to the instantaneous opening angle of dipole SR will reduce the spatial coherence of SR in horizontal direction in the beam size measurement by using interferometry. This reduction of spatial coherence is due to both of apparent change of the beam profile due to field depth and intensity distribution in the aperture. In the case of beam profile measurement by imaging system, observed beam profile will deform and produce a beam tail in asymmetric manner by this effect. This apparent change of beam profile, especially extra beam tail in one side has certain influence for beam halo measurement using the coronagraph, because it has a large dynamic range of 6 order magnitude. Since the magnitude of asymmetric tail is proportional to bending radius, this effect is larger in large high energy physics machine which has a long bending radius. This effect is theoretically studied and compare with coronagraph measurement result of beam halo in the SuperKEKB. As a conclusion, this effect is very small and not observable in the coronagraph measurement at SuperKEKB.  
poster icon Poster WEP005 [0.570 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2023-WEP005  
About • Received ※ 05 September 2023 — Revised ※ 09 September 2023 — Accepted ※ 13 September 2023 — Issue date ※ 21 September 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEP015 Synchrotron Light Monitor for the Advanced Photon Source Booster Synchrotron booster, synchrotron, photon, electron 358
 
  • K.P. Wootton, W. Berg, W.P. Burns III, J.R. Calvey, J.C. Dooling, L. Erwin, A.H. Lumpkin, N. Sereno, S.E. Shoaf, S.G. Wang
    ANL, Lemont, Illinois, USA
 
  Funding: This research used resources of the Advanced Photon Source, operated for the U.S. Department of Energy Office of Science by Argonne National Laboratory under Contract No. DE-AC02-06CH11357.
A new synchrotron light monitor has been tested for the booster synchrotron of the Advanced Photon Source. Visible light synchrotron radiation is collected by a mirror on a path tangential to the electron beam orbit, and directed to an optical imaging system and camera. This is planned to be a non-intercepting, transverse beam-size monitor even with the higher stored beam charges (~17 nC) needed for the Advanced Photon Source Upgrade. In the present work, we describe the present synchrotron radiation diagnostic layout. An analysis of the synchrotron radiation power on the mirror, the optical layout with components, and features of the control system will be presented.
 
poster icon Poster WEP015 [1.148 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2023-WEP015  
About • Received ※ 09 August 2023 — Revised ※ 08 September 2023 — Accepted ※ 14 September 2023 — Issue date ※ 02 October 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEP016 Beamline for Time Domain Photon Diagnostics at the Advanced Photon Source Upgrade photon, diagnostics, synchrotron, radiation 363
 
  • K.P. Wootton, W.X. Cheng, G. Decker, N. Sereno, F. Westferro
    ANL, Lemont, Illinois, USA
 
  Funding: This research used resources of the Advanced Photon Source, operated for the U.S. Department of Energy Office of Science by Argonne National Laboratory under Contract No. DE-AC02-06CH11357.
Time domain photon diagnostics are proposed for electron beam characterisation and operation of the Advanced Photon Source Upgrade storage ring. In the present work, we present updated status on the time-domain X-ray and visible photon diagnostic beamline for the Advanced Photon Source Upgrade. We outline design influences leading to the proposed beamline layout, in particular long-term maintenance and commonality with other beamlines at the Advanced Photon Source.
 
poster icon Poster WEP016 [0.812 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2023-WEP016  
About • Received ※ 10 August 2023 — Revised ※ 08 September 2023 — Accepted ※ 14 September 2023 — Issue date ※ 26 September 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEP020 Performance Evaluation of GAGG+ and Tungsten Carbide Blades in an X-ray Pinhole Camera photon, synchrotron, diagnostics, radiation 382
 
  • S.B. Burholt, L. Bobb, N. Vitoratou
    DLS, Harwell, United Kingdom
 
  At Diamond Light Source two X-ray pinhole cameras are used to measure the transverse profile of the 3 GeV electron beam. The current pinhole assembly is formed using tungsten blades with chemically etched shims to produce a 25 µm x 25 µm aperture and the imager incorporates a 0.2 mm LuAG:Ce scintillator. Tungsten carbide is a machinable high-Z material which at millimetre thicknesses is opaque to X-rays. With a slight change in pinhole design, similar to that already in place at the ESRF, tungsten carbide blades could offer a well-controlled aperture size for the pinhole camera with simpler assembly. Further to this, improvements to the photon yield of scintillators mean that the new scintillator GAGG+ has an almost two fold increase in yield compared to the current LuAG: Ce scintillator. An evaluation of the tungsten carbide blades and GAGG+ scintillator is presented.  
poster icon Poster WEP020 [0.468 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-IBIC2023-WEP020  
About • Received ※ 07 September 2023 — Revised ※ 08 September 2023 — Accepted ※ 13 September 2023 — Issue date ※ 24 September 2023
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)