Paper |
Title |
Page |
TU3I01 |
Commissioning of the LCLS-II Machine Protection System for MHz CW Beams |
154 |
|
- J.A. Mock, A.S. Fisher, R.T. Herbst, P. Krejcik, L. Sapozhnikov
SLAC, Menlo Park, California, USA
|
|
|
Beam power at the LCLS-II linac and FEL can be as high as several hundered kW with CW beam rates up to 1 MHz. The new MPS has a latency of less than 100 µs to prevent damage when a fault or beam loss is detected. The MPS architecture encompasses the multiple FEL beamlines served by the SC linac and can mitigate a fault in one beamline without impacting the beam rate in a neighboring beamline. The MPS receives inputs from various devices including loss monitors and charge monitors as well as magnet power supplies and BPMs to pre-emptively turn of the beam if a fault condition is detected. Link nodes distributed around the facility gather the input data and stream it back to a central processor that signals other link nodes connected to beam rate control devices. Commmissioning and experience with the new system will be described.
|
|
|
Slides TU3I01 [4.239 MB]
|
|
DOI • |
reference for this paper
※ doi:10.18429/JACoW-IBIC2023-TU3I01
|
|
About • |
Received ※ 06 September 2023 — Revised ※ 08 September 2023 — Accepted ※ 12 September 2023 — Issue date ※ 25 September 2023 |
Cite • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|