Paper |
Title |
Page |
MOP039 |
Transverse Multi-Bunch Feedback Detector Electronics Using Direct Sampling Analog-to-Digital Converters for the Synchrotron Radiation Source PETRA IV |
115 |
|
- S. Jabłoński, H.T. Duhme, U. Mavrič, S. Pfeiffer, H. Schlarb
DESY, Hamburg, Germany
|
|
|
PETRA IV, a new fourth generation synchrotron radiation source planned at DESY, will require a transverse multi-bunch feedback (T-MBFB) system to damp transverse instabilities and keep the beam emittance low. The critical part of the T-MBFB is a detector that must measure bunch-by-bunch, i.e. every 2 ns, beam position variations with the resolution not worse than 1 ¿m for the dynamic beam range of ±1 mm. In this paper, we present the conceptual design of the T-MBFB detector from the beam position pickups to the direct sampling ADCs. We analyse the noise sources limiting the detector resolution and present measurement results based on the evaluation modules.
|
|
DOI • |
reference for this paper
※ doi:10.18429/JACoW-IBIC2023-MOP039
|
|
About • |
Received ※ 01 September 2023 — Revised ※ 08 September 2023 — Accepted ※ 12 September 2023 — Issue date ※ 01 October 2023 |